This thermistor should be found attached to your water heaters exhaust. Anyway, whats the last time you flush your AO Smith Water Heater? Replace the control board. However, if it interrupts normal water heater operation, dont hesitate to call a plumber. Save my name, email, and website in this browser for the next time I comment. How long does an A.O. The initial setting is 120F, but you're in control after installation. Before you start to disassemble your water heater, remember to shut off its power and that you reassemble it correctly. Trouble codes on the AO Smith Water Heater mean your water heater is not working properly. Eccotemp Protection Plans are available for purchase within 60 days of your water heater purchase. If it doesnt throw a trouble code, make no beeping, or flashing light, and understand the water is functioning properly. Hi, On an Electric AO SMITH Smart Water Heater, if the diag light is a solid red (looks more orange) right after you flip breaker on and the smart panel has no lights/codes. Search For Support Documentation For Your A. O. Smith Brand Water Heater. Now, set the gas control knob to the Pilot position. With power turned off to the heater replace the upper element. FIX: Check if the remote controller is the right type, also connections between the water heater and remote. Smith offers a wide range of water heaters. Smith Water Heater, look no further! I had already unplugged the ESM and the problem persists. These cookies ensure basic functionalities and security features of the website, anonymously. Check if there is a gas leak. CODE: 341, Two timesPROBLEM: Exhaust thermistor failure. If the sensor fails to properly detect the temperature or it exceeds the limit, then the E05 error code appears. We will also tell you the solutions that will help you to fix the problem. Scale buildup on the heating element or on the bottom of the tank is one of the common reasons that can throw a wrench into work. Our comprehensive A.O. Finally, turn on your water heater and you can see the error code is gone. If everything seems to be in order but your water heater is still failing to ignite, then it is safer to call out a technician to take a look at it. Join our exclusive 2,500+ email list to get tailored advice, product roundups, and be the first to see our new content. From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: AO Smith 50 gallon electric water heater giving error code e55 for water leak d. The thin flow of water is typically a result of scaled-up pipes or improper water pressure. Otherwise, the status light wont blink. It is easy to recognize if there is a leak because bubbles will form. Its very simple to reset your AO Smith Electric Water Heater by following the below instructions: ECC stands for Electro-chemical compression. How to use diagnostic system and fix the problems using the error codes that appear on the remote controller. Scale is caused by water settling on heat transfer surfaces and the impurities build up into a hard, crusty layer. Related Repair Pages:A.O. Smith Signature 100 40-Gallon Tall 9-year Limited 40000-BTU Natural Gas Water Heater Model # G9-T4040NVR Find My Store for pricing and availability 614 Style: Tall Family Size: 3-4 People Warranty: 9-year limited A.O. You can see those error codes only on an AO Smith Water Heater with two or four chambers. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Our product specs, warranty sheets, installation guides, and user manuals are online. Smith University | An Education in Hotwater Register NOW for live online workshops! To have the unit working properly, it has to be supplied with the power and correct connection. A.O. Fix the loose wiring and replace the damaged wires. Learn how to inspect and replace a water heater dip tube and solve the problems related to not enough hot water or sediment buildup. Now, turn the electric power on to your water heater. It may not display this or other websites correctly. What Does Flashing Light Mean On Ao Smith Water Heater? This cookie is set by GDPR Cookie Consent plugin. Install a new gas control valve and tighten it up using the 4 gas pipe by turning it clockwise. According to the instruction, they also have to make the distance between the intake terminals and the exhaust terminal. I hav been reading some similar posts regarding this issue, and I think I have made the proper analysis. To solve this problem, you will need to find the correct settings for your water heaters model and reset them on the computer board. And this tutorial will help in replacing the thermocouple on the AO Smith Water Heater: Secondly, inspect the wire connectors for loose. They have to make sure that it can function properly. Once the thermopile reaches its operating temperature, the status light will no longer remain solid red. Find the right water heater for your needs. And this guide on AO Smith Water Heater Troubleshooting Lights broke down everything you need to know. And secondly, loose wiring connections can also cause this symptom. Malfunctioning Control Board 4. Built in dry fire protection will not allow the water heater to be turned on unless the tank is full of water, eliminating accidentally burning out the upper element. We and our partners use cookies to Store and/or access information on a device. As a result, the heating element stops warming the water. This website uses cookies to improve your experience while you navigate through the website. The consent submitted will only be used for data processing originating from this website. Shorted Heating Elements 5. Manual for 400 - 1000 models. A water heater leaks from different places like from the top, bottom, and side. Too High Temperature 2. The national average is 67.5. The consent submitted will only be used for data processing originating from this website. Your AO Smith Water Heater wont light up if there are electrical problems like the thermopile wires come loose. If you have either a 2-chamber or 4-chamber model of AO Smith Water Heater, you can see the trouble codes E20, E21, E22, E23, and E24 for a single reason. Main Menu. Generally, the heating element, top of the unit, tank, and drain valve are some common places from where the water is leaking. Now, remove the ground joint union in the gas piping and disconnect the remaining piping from the gas control valve. However, I highly recommend you call a certified plumber to solve this issue. Smith Water Heater Parts. Smith - Troubleshooting help - Hello my frist post here. Solution: Check for the soot on the AFR rod, wire connection, and breakage. FIX: See error code 331, 321 and 311. Here are some error codes which can be learned. Low water flow and loose wiring also contribute to the Pentair Mastertemp e05 code. This cookie is set by GDPR Cookie Consent plugin. Your AO Smith Water Heater will throw the error code E04 when it detects moisture or leak in the heater. FIX: Check if the condensate drain is installed on the vent collar of the heater. Solution: Check for connection and breakage of wires, burn marks on the computer board, and power supply to the unit. Need sanity check to make sure I troubleshoot the device properly: Problem: No ignition. This error code signifies that there is a problem with your outlet thermistor. Note: You can also read how to fix the Pentair heater error codes problem. Solution: Check for connection and wire breakage or computer board failure (burn marks). The water heater is surely essential to support modern households, and we can make sure that people will look for the best water heater which can be used for their household needs. First off, turn the gas control knob to the off position. In this case, you must flush the unit. This error should really be addressed by a technician, but you can also open up your water heater to check for any wire breakages or loose connections. Use the AO Smith code guide to find the main causes and solutions for the problems of the following models: 110, 310, 510, 240, 340, and 540 series, for safety, convenience, and great savings. Solution: Check the wire connection for looseness or breakage. This is a popular problem that a lot of AO Smith tankless water heater owners suffer from because this error code usually occurs when there is an ignition failure. What does ECC code mean A.O. CODE: 661, Four timesPROBLEM: Bypass valve fault (only model 540). A thin or low flow of water to or from the water heater can also cause the e05 on Pentair heater display. On the other hand, your AO Smith Water Heater goes through problems if the status light flashes more than 1 times followed by a three-second pause. This numerical code is telling you about the ignition failure. Tank Guard gives you advanced tank protectionextends the life of your water heater. AO Smith electric water heater keeps shutting off, e02 mike4500 Jun 18, 2019 M mike4500 Premium Member Joined Jun 18, 2019 Messages 5 Location NJ Jun 18, 2019 #1 Model Number 50 g Brand -brand- Age 1-5 years I have an AO Smith 50 gallon with the electronic display. Leak Shield shut off valve automatically shuts off watersupply when a leak is detected (accessoryincluded). If you're looking for help fixing your A.O. It will be best to consult with a certified professional or the technical support team. to control or estimate. This prevents proper connectivity between the system and the sensor, causing the heater to shut down and display the E05 error code. 113 Flame On Should be Off Fail Now, relight the pilot light by following the step-by-step guide I mentioned earlier in this article. CODE: 11 (111), Three timesPROBLEM: The ignition failure. Wait for ten minutes to allow all the gas to clear out. It functions just like an outlet thermistor, but is found on your inlet pipes instead of your outlet pipes. F05 - E02 - Door lock fault F08 - E01 - Waterfill fault I've looked up the error codes for these, and am just getting started diagnosing the issue. Connect the water line and turn on the heater to see the flow of water. I checked all the wires and didn't find any problems, frayed insulation, etc. How to use a diagnostic system to repair a faulty heater. To solve this issue, you need to check for any condensation within the heater. document.write(intYear); Some of the problems are common, and they do not include an error code: Water is not hot enough or is too hot The temperature of the exiting water fluctuates Noise Burner does not ignite Long time to get hot water Sediment buildup If there is no scale build up, then you should check the connections and wires around the flow adjustment valve. The leak of carbon monoxide is one of the carbon monoxide poisoning causes. You can hear the buzzing of the spark igniter. You must log in or register to reply here. This debris will be what is preventing your water heater from functioning properly. Then, leave the unit for 10 minutes to let the thermopile cool down. Error code 510 (LED flashes six times) Problem: Gas solenoid valve malfunction. Is there leaking from the heat exchanger? Is the surrounding air contaminated? In contrast, 4 consecutive flashes with a 3-second pause indicates the temperature sensor of the unit senses the water temperature is too high. Previous replacement, improper installation and other conditions, outside the manufacturer's control and requirements for warranty may prevent reimbursement. We are going to cover some of the most common error codes and problems seen with the AO Smith tankless water heater so you know what you can do when the issue occurs. Legal Disclosure:Lildutchuncle.com provides and shares information on plumbing, heating & air quality, home improvement, and other DIY projects. However, a few hours later I get the blinking red light (2 flashes) and the unit stops heating water. Smith maintains its leading position in the market. AO Smith tankless water heaters equipped with the remote controller have a great advantage; a self-diagnosing function that helps in diagnosing the heating problem. 13 February 2021; Non class; 0 Comments For a better experience, please enable JavaScript in your browser before proceeding. The LED status light flashes 0 times or it doesnt come on due to two reasons. var intYear = dteNow.getFullYear(); Its normal. Thank you. Jenn-Air JGS8750ADB Control Panel Burning Hot! Smith Water Heater, look no further! ao smith water heater error code e05. This error code is usually a sign that there is some kind of blockage in your vents, gas burner or fan motor. They only need to check if there is any blockage in the vents. I highly recommend you use a multimeter to test the continuity of them and replace them if needed. Dirty/Blocked Filter How To Reset AO Smith Water Heater Easily FAQs: What are the common problems of the AO Smith water heater? Premium 5500 Watt Stainless Steel Heating Elements are more efficient and longer lasting than conventional elements, with higher recovery. Your AO Smith Water Heater will make a beep once it detects a problem to notify you that something is going wrong with the unit. Copyright 2020 - 2022 | All rights reserved. AO Smith Water Heater will throw an error code or make a beeping noise if the unit is not working properly. This is the error code that shows people that the dipswitch settings are incorrect. Just hire a certified technician to do this for you. You should also ensure they are securely attached. These cookies track visitors across websites and collect information to provide customized ads. People can find those advantages from AO Smith tankless water heater. Blue light now heartbeat dim & bright. 12-Year limited residential warranty gives you peace of mind. In this case, the pilot light will be lit but the thermopile fails to generate the required output voltage. The solution for this problem is by checking the Hi-limit switch. The average cost per kWh is ${{ELECTRICITYPRICE}} Problem: Bypass valve fault (only model 540). Though resetting the unit will fix and clear the error code, you must figure out whats overheating the water. Second, turn on a hot water faucet anywhere in your house to let the air out of the waterline. Follow the below steps to change the part correctly: Your AO Smith Water Heaters status light will blink 5 times every three seconds if the temperature sensor gets defective. Re-attach the control box cover, and restore power to the water heater. If you want to increase the water heater thermostat(s) setting(s), A.O. However, there is a four pin white plug in the water heaters junction box that I believe is the connector for the smart grid module, and two of the wires have come out of the pin/connector. Now, back the electric power to your water heater and it will clear those faulty codes. Learn about AO Smith tankless error codes for easy and inexpensive troubleshooting. Status light blinking once every 3 seconds but I dont see a flame in the window. Is there leaking from the heat exchanger? If they come loose, tighten them up. Smith Show 161 Results Brand: A.O. Then, find the source of the water leak. Legal Disclosure:Lildutchuncle.com provides and shares information on plumbing, heating & air quality, home improvement, and other DIY projects. Clean the gas pipes properly if they are clogged and do not forget to turn off the valve before cleaning. An example of data being processed may be a unique identifier stored in a cookie. I have tested the power at the thermostat and the elements with a multi meter and they all check out fine. To fix this issue, you should replace the control board. It is a 50 gallon A O Smith just installed in new home 6 months ago.LG12-50R55DV 210. Ask a customer care specialist GCVL40-200 GCVL40-201 GNR40100 GNR50100 GPS-75 GPVH40100. Finally, install the thermostat professionally if it doesnt fit against the tank snugly. The Pentair heater e05 error code is one of the 12 error codes for this pool heater. Save my name, email, and website in this browser for the next time I comment. Once you have, make sure all the connections are secure and safe and clean away any dirt or debris that could be the issue. If you're looking for help fixing your A.O. Comprehensive information about your new appliance - from getting started to cleaning and maintenance - with answers to frequently asked questions. If your display screen is showing this error code and is flashing twice, then this is a sign that there is a problem with your water heaters air-fuel ratio rod (sometimes referred to as the AFR for short). Make sure that you maintain a cleaning schedule to keep the pipes clear and functional. There are a range of potential causes to this error. Release the gas control knob once the status light starts flashing and set the temperature to your desired setting. The air-fuel ratio rod (AFR) is faulty. Once your inlet thermistor is clean and properly connected, then the error code should vanish and your water heater return to its usual state. The status light flashes 1 times with a three-second pause indicating your water heater operates at its tip-top condition. Does the status light of your AO Smith Water Heater remain solid red? It also causes the heater to shut down completely and display the E05 code on the Pentair heater. ECS40200 FPCR50260E GCNH30100 GCNH50100 GCV30 GCV40. If it's shorted out, unplug the machine . smith gas water heater installation user and service manual (102 pages) Water Heater A.O.Smith GPSX-50L Owner's Manual. However, we often suggest professional help if the issue is complex. Remove the access panel and fold away the insulation. Home | Sitemap | Blog| Privacy | Disclaimer | Contact| About. Turn the gas control knob to the off position by moving it counter-clockwise.