It loses about 1.5 to 2 hours per day without any outages. If all looks well, and the gears are still not turning, you may need to replace the mechanism. Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. Almost like it doesnt have the strength to click the timer on or off. The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving. What is the problem? It is not warped in any way. I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. Can breaker be bad? It just seems to have a weak start?? Any advice on how to fix. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. Welcome to Pool Spa Outpost! Any idea what may be causing this? I looked to see if the gears on the timer are running. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? There is a switch control panel and replaced the 20amps DP switch as well. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
We may earn a small commission. The position of the metal bar forces the gear next to it to turn one way or another. A recent power outage will cause the timer to stop working. BUILT BY HAND IN QUEENS, NYC. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Help! Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. Or the switch can suffer wear over many years, and might not make solid contact. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. Recently i just notice my T104R timer a bit noisier than usual. I bought a new motor for mine after 20 years and learned about this the hard way. Set the current time to the center time pointer, pointing downward at 6 oclock. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. 3 Baths. If you cant see an issue with the gears, then it could be the timer motor. Sound right? Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! If you have gone back after a few hours and the pins have moved that means you have electrical power to your timer and it is working. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. It started lagging again a week or so ago. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. My pool pump and skimmer are on two different motors. When you flip the switch does it separate and reconnect the tabs? It is generally not recommended to reuse a critical fastener like the rear spinal nut on your 2000 Ford Focus. Take a good look at the position of the pins and write down the locations. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. You off course will want to adjust one time pin at a time. I called Intermatic and there is nothing you can do except check it every time you have a power loss. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. VIDEO TOUR. The problem is the 'off' tripper. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. HELP! Ft. 750 Joshua Dr, Hollister, CA 95023. ), you should be able to discern if this is the problem, which could mean a new clock. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . My time clock has an ant infestation! Any ideas? "headline": "Intermatic Pool Timer Troubleshooting",
The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. Pop-in a new timer mechanism, and replace the wires to the previous configuration. Then remove the mechanism by pressing the clip at the top of the timer box. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. Did the power recently go out or has the circuit breaker tripped? If you dont have the voltage here you have an issue with either the wiring or the breaker. (For outside light timer) The one before was original to the house & I had no trouble. If you are not sure if your timer is working or not you will first need to know if its even operational. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. With this model can I control both of these motors with two different on and off times. Confused. I manually turn it on timer is running, it will trip pump OFF. Does the motor gradually start running slowly? by pool co. , so wondered about the cost. So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. It was always fine before. Off flipper always works. Does the tripper work on other areas of the clock, like near the off tripper? Is the timer repairable, or should I just install a new one? Turn in either direction and align the exact time-of-day on . The time does not advance after resetting. Open following links to identify timer and then add a comment. And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. My timer works good it turns on and off when I set the time. Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. You can check these easily by removing them and inspecting them for damage. AJH Trade Group also participate in other affiliate programs. They should be straight, if not, replace them. "@type": "BlogPosting",
It sounds like the Line and Load wires are reversed. I have a sweeper set on auto on the second timer and it is working correctly. We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. the timer was directly plugged into a gfci and the pump directly into the timer. "@type": "Person",
Thank you. Back when I was a young technician I was taught to always look for the easy things and use all my senses. Push the tab on the top, and let the mechanism fall forward. Ask Your Own Pool and Spa Question When I put the new one on, the trippers do not work. the problem lies, where the power dies as they say.
You can replace the entire mechanism or the gears. Thanks. And Ive noticed lately that the ON is not functioning all the time. Just above the yellow clock youll see some holes. You most likely just need to now set the pins and the clock and your timer will work. I have to reset the time every day. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. The timer seems to get stuck prior to reaching the on trippers therfore the pump cant turn on. Did I wire it incorrectly or did I just get a bad timer? Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Switch the breaker off at the power board. It should sit down nicely. The terminals on the wires aren't tight. Go for it, a little maintenance expense. Grab it, pull it towards you, move it around then place it back down. Donna Simpson Eating Website But What Toilet? Until it came in, I manually turned on and the tripper turned it off. Any ideas why its doing that? I have an intermatic timer thats 2 years young. Replaced complete new timer assuming 5 years perfect service probably wore it out. This is hard to check if you are not qualified. Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts Replacement for T100 Series and Intermatic Time Clocks T101, T102, T103, T104, Pool Timer On Off Clips(4 ON / 4 Off / 8 Screws) : Amazon.com.au: Home Improvement The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. Your email address will not be published. It just stays at that time. Just installed a new timer. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. Turn the power off at the breaker box and carefully remove the wires to the clock. I have Model T40004RTe. A power surge may have taken out the timer or the pump. "caption": "In The Swim Blog"
Is there a separate switch somewhere between breaker and timer? Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Reset the clock to the correct time. We cover T101, T103 and T104 models of mechanical pool timers. Hi Davy, Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. But my new timer will not work either. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. All Rights Reserved. First, you need to set the time, which is good to know in case of a power outage, or daylight savings adjustments. Check that dial is not warped. My intermatic pool timer will not automatically turn on. Do you have an answer to why my pump wont turn off or on? Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. Is it Necessary? Replace the plastic insulator cover, turn on the power, and observe the visual motor check. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. be sure the pins are pushed onto the edge of the dial fully.